Asincronías paciente - ventilador

Av: Medverkande: Materialtyp: ArtikelUtgivningsinformation: Editorial de la universidad Santiago de Cali Universidad Santiago de Cali 2024Beskrivning: 1 electronic resource (147-174 p.)Innehållstyp:
  • text
Medietyp:
  • computer
Bärartyp:
  • online resource
Ämnen: Onlineresurser: I: Sammanfattning: Asynchronies in mechanical ventilation are a process that can interfere with ventilation with the patient in critical condition. These may be due to problems in the patient (neuronal) or due to the programming of mechanical ventilation. Asynchrony can occur during ventilator triggering, in the inspiration period after triggering, in the transition from inspiration to expiration, and in the expiratory phase. Asynchronies decrease comfort, prolong mechanical ventilation, increase the stay in the Intensive Care Unit and may increase mortality. Therefore, it is important to understand and correct the cause of the asynchrony and thus provide adequate pulmonary ventilation.Sammanfattning: Las asincronías en ventilación mecánica son un proceso que puede interferir en la ventilación con el paciente en estado crítico, estas pueden deberse a problemas en el paciente (neuronal) o debido a la programación de la ventilación mecánica. La asincronía puede presentarse durante el disparo del ventilador, en el periodo de inspiración después del disparo, en la transición de inspiración a espiración, y en la fase espiratoria. Las asincronías disminuyen el confort, prolonga la ventilación mecánica, aumenta la estancia en la Unidad de Cuidados Intensivos y puede incrementar la mortalidad. Por lo tanto, es importante comprender y corregir la causa de la asincronía y ofrecer de esta manera una adecuada ventilación pulmonar.
Inga fysiska exemplar för denna post

Open Access Unrestricted online access star

Asynchronies in mechanical ventilation are a process that can interfere with ventilation with the patient in critical condition. These may be due to problems in the patient (neuronal) or due to the programming of mechanical ventilation. Asynchrony can occur during ventilator triggering, in the inspiration period after triggering, in the transition from inspiration to expiration, and in the expiratory phase. Asynchronies decrease comfort, prolong mechanical ventilation, increase the stay in the Intensive Care Unit and may increase mortality. Therefore, it is important to understand and correct the cause of the asynchrony and thus provide adequate pulmonary ventilation.

Las asincronías en ventilación mecánica son un proceso que puede interferir en la ventilación con el paciente en estado crítico, estas pueden deberse a problemas en el paciente (neuronal) o debido a la programación de la ventilación mecánica. La asincronía puede presentarse durante el disparo del ventilador, en el periodo de inspiración después del disparo, en la transición de inspiración a espiración, y en la fase espiratoria. Las asincronías disminuyen el confort, prolonga la ventilación mecánica, aumenta la estancia en la Unidad de Cuidados Intensivos y puede incrementar la mortalidad. Por lo tanto, es importante comprender y corregir la causa de la asincronía y ofrecer de esta manera una adecuada ventilación pulmonar.

Creative Commons Licence cc by-nc-nd cc https://creativecommons.org/licenses/by-nc-nd/4.0/

spa

Freely available e-book